ABB VB6-30-01-03 Mini Rev.Contactor 48V 40-450Hz

0.00

The VB6-30-01 mini reversing contactor is a compact 3 pole contactor with 1 auxiliary contact, screw terminals and normal mechanical interlock. They are ideally suited for applications where reliability is a must and space is at a premium. Mini reversing contactors are used in residential buldings, commercial buildings and industrial applications for the control of three-phase motor loads up to 4 kW (AC-3). Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.

Description

Dimensions

  • Product Net Width:
    96.5 mm
  • Product Net Height:
    57.5 mm
  • Product Net Depth / Length:
    46.5 mm
  • Product Net Weight:
    0.355 kg

Technical

    • Number of Poles:
      3
    • Rated Operational Voltage:
      Auxiliary Circuit 690 V AC
      Auxiliary Circuit 250 V DC
      Main Circuit 690 V AC
      Main Circuit 220 V DC
    • Rated Frequency (f):
      Control Circuit 400 Hz
      Control Circuit 50 Hz
      Control Circuit 60 Hz
      Main Circuit 60 Hz
      Main Circuit 50 Hz
      Main Circuit DC
    • Rated Impulse Withstand Voltage (Uimp):
      Main Circuit 6 kV
    • Rated Insulation Voltage (Ui):
      690 V
      acc. to UL/CSA 600 V
    • Number of Main Contacts NC:
      0
    • Number of Main Contacts NO:
      3
    • Rated Operational Current AC-1 (Ie):
      (220 / 240 V) 40 °C 20 A
      (220 / 240 V) 55 °C 16 A
      (380 / 440 V) 40 °C 20 A
      (380 / 440 V) 55 °C 16 A
      (690 V) 40 °C 6 A
      (690 V) 55 °C 6 A
    • Rated Operational Power AC-3 (Pe):
      (230 V) Three Phase 2.2 kW
      (400 V) Three Phase 4 kW
      (500 V) Three Phase 4 kW
      (690 V) Three Phase, NC 3 kW
      (690 V) Three Phase, NO 3 kW
    • Rated Short-time Withstand Current (Icw):
      at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
    • Number of Auxiliary Contacts NC:
      1
    • Number of Auxiliary Contacts NO:
      0
    • Rated Operational Current AC-15 (Ie):
      (440 V AC) 3 A
      (24 V) 4 A
      (120 V) 4 A
      (240 V) 4 A
      (500 V) 2 A
      (380 / 400 V) 3 A
    • Rated Operational Current DC-13 (Ie):
      (24 V) 2.5 A
      (110 V) 0.7 A
      (220 / 240 V) 0.4 A
    • Conventional Free-air Thermal Current (Ith):
      Main Circuit 20 A
    • Rated Control Circuit Voltage (Uc):
      48 V AC
    • Coil Operating Limits:
      (acc. to IEC 60947-4-1) for AC supply 0.85 … 1.1 x Uc (at θ ≤ 55 °C)
      (acc. to IEC 60947-4-1) for DC supply 0.85 … 1.1 x Uc (at θ ≤ 55 °C)
    • Degree of Protection:
      Auxiliary Circuit Terminals IP20
      Control Circuit Terminals IP20
      Main Circuit Terminals IP20
    • Pollution Degree:
      3
    • Mechanical Durability:
      10000000 cycle
    • Minimum Switching Capacity:
      Auxiliary Circuit 17 V
      Auxiliary Circuit 5 mA
    • Maximum Electrical Switching Frequency:
      (AC-1) 300 cycles per hour
      (AC-15) 600 cycles per hour
      (AC-3) 600 cycles per hour
      (DC-1) 600 cycles per hour
      (DC-13) 600 cycles per hour
      (DC-3) 600 cycles per hour
    • Connecting Capacity Main Circuit:
      Flexible with Ferrule 1/2x 1 … 2.5 mm²
      Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm²
      Flexible 1/2x 1 … 2.5 mm²
      Rigid 1/2x 1 … 4 mm²
    • Connecting Capacity Auxiliary Circuit:
      Flexible with Ferrule 1/2x 1 … 2.5 mm²
      Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm²
      Flexible 1/2x 1 … 2.5 mm²
      Rigid 1/2x 1 … 4 mm²
    • Connecting Capacity Control Circuit:
      Flexible with Ferrule 1/2x 1 … 2.5 mm²
      Flexible with Insulated Ferrule 1/2x 1 … 2.5 mm²
      Flexible 1/2x 1 … 2.5 mm²
      Rigid 1/2x 1 … 4 mm²
    • Wire Stripping Length:
      Auxiliary Circuit 9 mm
      Main Circuit 9 mm
    • Tightening Torque:
      Control Circuit 0.8 … 1.1 N·m
      Main Circuit 0.8 … 1.1 N·m
    • Mounting on DIN Rail:
      TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
      TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    • Power Loss:
      at Rated Operating Conditions per Pole 2 W
    • Standards:
      IEC/EN 60947-1
      IEC/EN 60947-4-1
      IEC/EN 60947-5-1
      UL 60947-1
      UL 60947-4-1

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V AC
  • Full Load Amps Motor Use:
    (240 V AC) Single Phase 4.9 A
    (440 … 480 V AC) Three Phase 4.8 A
  • Horsepower Rating UL/CSA:
    (208 V AC) Three Phase 1 Hp
    (220 … 240 V AC) Single Phase 0.5 Hp
    (220 … 240 V AC) Three Phase 2 Hp
    (440 … 480 V AC) Three Phase 3 Hp
    (550 … 600 V AC) Three Phase 1 Hp
  • General Use Rating UL/CSA:
    (300 V AC) 12 A
  • Connecting Capacity Main Circuit UL/CSA:
    Stranded 1/2x 22-10 AWG
  • Connecting Capacity Auxiliary Circuit UL/CSA:
    Stranded 1/2x 22-10 AWG
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 7 in·lb
    Control Circuit 7 in·lb
    Main Circuit 7 in·lb

Environmental

  • Ambient Air Temperature:
    Operation -20 … +55 °C
    Storage -40 … +80 °C
  • Maximum Operating Altitude Permissible:
    2000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    11 ms Pulse 15g
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5g / 5 … 150 Hz
  • RoHS Status:
    Following EU Directive 2011/65/EU

Additional information

Brand

ABB

Type

Contactor