ABB AF38-30-00-11 24-60V50/60HZ 20-60VDC Contactor

AF38 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 1-stack 3-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available

Description

Number of Main Contacts NO 3
Mounted Aux Contacts 0 NO, 0 NC
Max Mechanical Switching Frequency 3600 cycles per hour
Max Electrical Switching Frequency AC-1 600 cycles per hour, AC-2 / AC-4 150 cycles per hour, AC-3 1200 cycles per hour
Horsepower Rating UL/CSA (220 … 240 V AC) Three Phase 10 hp, (440 … 480 V AC) Three Phase 25 hp, (550 … 600 V AC) Three Phase 30 hp, (120 V AC) Single Phase 2 hp, (200 … 208 V AC) Three Phase 10 hp, (240 V AC) Single Phase 5 hp
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 ampere
Terminal Type Screw Terminals
Rated Operational Voltage Main Circuit 690 volt
Operate Time Between Coil De-energization and NC Contact Closing 13 … 98 millisecond, Between Coil De-energization and NO Contact Opening 11 … 95 millisecond, Between Coil Energization and NC Contact Opening 38 … 90 millisecond, Between Coil Energization and NO
Rated Control Circuit Voltage (Uc) 50 Hz 24-60V; 50 Hz / 60 Hz 24-60V; 60 Hz 24-60V; DC Operation 20-60V
Rated Operational Power AC-3 (Pe) (220 / 230 / 240 V) 11 KWT, (380 / 400 V) 18.5 KWT, (415 V) 18.5 KWT, (440 V) 22 KWT, (500 V) 22 KWT, (690 V) 22 KWT, (400 V) 18.5 KWT
Rated Operational Current AC-3 (Ie) (220 / 230 / 240 V) 60 °C 40 ampere, (380 / 400 V) 60 °C 38 ampere, (415 V) 60 °C 38 ampere, (440 V) 60 °C 38 ampere, (500 V) 60 °C 33 ampere, (690 V) 60 °C 24 ampere
Rated Operational Current AC-1 (Ie) (690 V) 40 °C 50 ampere, (690 V) 60 °C 42 ampere, (690 V) 70 °C 37 ampere
Rated Frequency (f) Main Circuit 50 / 60 hertz
Rated Short-time Withstand Current (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 ampere, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 ampere, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 ampere, at 40 °C Ambient Temp, in Free Air, from
Package Width 87 millimetre
Package Length 87 millimetre
Package Height 47 millimetre
Invoice Description AF38-30-00-11 24-60V50/60HZ 20-60VDC Contactor
Product Range AF38
Package Gross Weight 0.31 kilogram
Extended Product Type AF38-30-00-11
General Use Rating UL/CSA (600 V AC) 50 ampere
Full Load Amps Motor Use (440 … 480 V AC) Three Phase 25 ampere, (550 … 600 V AC) Three Phase 30 ampere, (120 V AC) Single Phase 2 ampere, (200 … 208 V AC) Three Phase 10 ampere, (220 … 240 V AC) Three Phase 10 ampere, (240 V AC) Single Phase 5 ampere
Ambient Air Temperature Close to Contactor for Storage -60 … +80 degree Celsius, Close to Contactor without Thermal O/L Relay -40 … +70 degree Celsius, Close to Contactor Fitted with Thermal O/L Relay -25 … +60 degree Celsius
Rated Insulation Voltage (Ui) acc. to UL/CSA 600 volt, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 volt
Product Class Block ContactorsBlock Contactors
Total GST Percentage 18.00