Description
Technical Specifications | Details |
---|---|
Setting Range | 18 … 25 A |
Rated Operational Voltage | |
Auxiliary Circuit | 440 V DC, 500 V AC |
Main Circuit | 690 V AC, 440 V DC |
Rated Operational Current (Ie) | 25 A |
Rated Frequency (f) | |
Auxiliary Circuit | 50 Hz, 60 Hz, DC |
Main Circuit | 60 Hz, 50 Hz, DC |
Rated Impulse Withstand Voltage (Uimp) | |
Auxiliary Circuit | 6 kV |
Main Circuit | 6 kV |
Rated Insulation Voltage (Ui) | 690 V |
Number of Poles | 3 |
Number of Auxiliary Contacts NC | 1 |
Number of Auxiliary Contacts NO | 1 |
Number of Protected Poles | 3 |
Conventional Free-air Thermal Current (Ith) | |
Auxiliary Circuit NC | 10 A |
Auxiliary Circuit NO | 6 A |
Rated Operational Current AC-15 (Ie) | |
(120 V) NC | 3 A |
(120 V) NO | 1.5 A |
(240 V) NC | 3 A |
(240 V) NO | 1.2 A |
(400 V) NC | 0.75 A |
(400 V) NO | 0.37 A |
(440 V) NC | 0.75 A |
(440 V) NO | 0.37 A |
(500 V) NC | 0.3 A |
(500 V) NO | 0.25 A |
Rated Operational Current DC-13 (Ie) | |
(125 V) NC | 0.25 A |
(125 V) NO | 0.25 A |
(24 V) NC | 1.25 A |
(24 V) NO | 1.25 A |
(250 V) NC | 0.12 A |
(250 V) NO | 0.04 A |
(60 V) NC | 0.25 A |
(60 V) NO | 0.25 A |
Degree of Protection | |
Housing | IP20 |
Main Circuit Terminals | IP10 |
Pollution Degree | 3 |
Connecting Capacity Auxiliary Circuit | |
Flexible with Ferrule | 1/2x 0.75 … 2.5 mm² |
Flexible | 1/2x 0.75 … 2.5 mm² |
Rigid | 1/2x 0.75 … 4 mm² |
Connecting Capacity Main Circuit | |
Flexible with Ferrule | 1/2x 1.5 … 4 mm² |
Flexible | 1/2x 1.5 … 4 mm² |
Rigid | 1/2x 1.5 … 6 mm² |
Tightening Torque | |
Auxiliary Circuit | 1 … 1.3 N·m |
Main Circuit | 1.5 … 1.9 N·m |
Wire Stripping Length | |
Auxiliary Circuit | 9 mm |
Main Circuit | 12 mm |
Recommended Screw Driver | |
Auxiliary Circuit | Pozidriv 1 |
Main Circuit | Pozidriv 2 |
Power Loss | |
at Rated Operating Conditions per Pole | 1.5 … 2.9 W |
Suitable For | A9, A12, A16, A26, A30, A40, AL9, AL12, AL16, AL26 |