ABB Contactor AL9-30-10 240V DC

0.00

General Information

  • Extended Product Type:
    AL9-30-10 240V DC
  • Product ID:
    1SBL143001R8910
  • EAN:
    3471522268891
  • Catalog Description:
    AL9-30-10 240V DC Contactor
  • Long Description:
    AL 9 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AL… series 1-stack 3-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks – Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected – Accessories: a wide range of accessories is available. AL… contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Description

Dimensions

  • Product Net Width:
    44 mm
  • Product Net Depth / Length:
    97 mm
  • Product Net Height:
    78 mm
  • Product Net Weight:
    0.52 kg

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    0
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
    Supply Circuit 50 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A
    acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 °C 25
    (690 V) 55 °C 22
    (690 V) 70 °C 18
  • Rated Operational Current AC-3 (Ie):
    (415 V) 55 °C 9 A
    (440 V) 55 °C 9 A
    (500 V) 55 °C 9 A
    (690 V) 55 °C 7 A
    (380 / 400 V) 55 °C 9 A
    (220 / 230 / 240 V) 55 °C 9
  • Rated Operational Power AC-3 (Pe):
    (415 V) 4 kW
    (440 V) 4 kW
    (500 V) 5.5 kW
    (690 V) 5.5 kW
    (380 / 400 V) 4 kW
    (220 / 230 / 240 V) 2.2 kW
    • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
      8 x Ie AC-3
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
      10 x Ie AC-3
    • Rated Operational Current AC-15 (Ie):
      (500 V) 2 A
      (690 V) 2 A
      (24 / 127 V) 6 A
      (220 / 240 V) 4 A
      (380 / 400 V) 3 A
    • Short-Circuit Protective Devices:
      Auxiliary Circuit – gG Type Fuses 10 A
      gG Type Fuses 25 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A
    • Maximum Electrical Switching Frequency:
      (AC-1) 600 cycles per hour
      (AC-2 / AC-4) 300 cycles per hour
      (AC-3) 1200 cycles per hour
    • Rated Operational Current DC-13 (Ie):
      (24 V) 6 / 144 A
      (48 V) 2.8 / 134 A
      (72 V) 2 / 144 A
      (125 V) 1.1 / 138 A
      (250 V) 0.55 / 138 A
    • Rated Insulation Voltage (Ui):
      acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
      acc. to UL/CSA 600 V
    • Rated Impulse Withstand Voltage (Uimp):
      8 kV
    • Mechanical Durability:
      10 million
    • Maximum Mechanical Switching Frequency:
      3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
      DC Operation 240 V
    • Coil Consumption:
      Average Holding Value, from Warm State 3 W
      Average Pull-in Value, from Cold State 3 W
    • Operate Time:
      Between Coil De-energization and NC Contact Closing 16 … 27 ms
      Between Coil De-energization and NO Contact Opening 10 … 17 ms
      Between Coil Energization and NO Contact Closing 50 … 100 ms
    • Connecting Capacity Main Circuit:
      Flexible with Cable End 0.75 … 2.5 mm²
      Rigid Cable 1 … 4 mm²
    • Connecting Capacity Auxiliary Circuit:
      Flexible with Cable End 0.75 … 2.5 mm²
      Rigid Cable 1 … 4 mm²
    • Degree of Protection:
      acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    • Connecting Terminals (delivered in open position) Main Poles:
      M 3.5 (+,-) pozidriv 2 screw with cable clamp
    • Terminal Type:
      Screw Terminals

    Environmental

    • Ambient Air Temperature:
      Close to Contactor Fitted with Thermal O/L Relay -25 … +55 °C
      Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … +55 °C
      Close to Contactor without Thermal O/L Relay (Uc) -40 … +70 °C
      Close to Contactor for Storage -60 … +80 °C
    • Climatic Withstand:
      acc. to IEC 60068-2-30 and 60068-2-11 – UTE C 63-100 specification II
    • Maximum Operating Altitude Permissible:
      3000 m
    • Resistance to Shock acc. to IEC 60068-2-27:
      Closed, Shock Direction: A 20 K40
      Closed, Shock Direction: B1 15 K40
      Closed, Shock Direction: C1 20 K40
      Closed, Shock Direction: C2 14 K40
      Open, Shock Direction: A 10 K40
      Open, Shock Direction: B1 5 K40
      Open, Shock Direction: C1 8 K40
      Open, Shock Direction: C2 8 K40
      Shock Direction: B2 10 K40
    • RoHS Status:
      Following EU Directive 2011/65/EU